Product Identification

Product ID:HENRY 317 MULTI-PURPOSE PANEL & CONSTRUCTION ADHESIVE
MSDS Date:01/01/1997
FSC:8040
NIIN:00N082120
MSDS Number: CGCGT

Responsible Party
ARMSTRONG WORLD INDUSTRIES INC
313 WEST LIBERTY ST
LANCASTER, PA 17604
US

Emergency Phone: 717-396-2328; 717-396-2935

Info Phone: 717-396-2328; 717-396-2935

Cage: 6F167

Contractor
ARMSTRONG WORLD INDUSTRIES INC
LANCASTER, PA 17604 US

Telephone: 717-396-2328;717-396-2935

Cage: 6F167

Ingredients

MINERAL OIL, PETROLEUM EXTRACTS, HEAVY NAPHTHENIC

CAS: 64742-11-6

RTECS: PY8042000

Fraction By Weight: 5-10%

OSHA PEL 300 PPM

ACGIH TLV: 300 PPM


LACOLENE; (ALIPHATIC PETROLEUM DISTILLATES)

CAS: 64742-89-8

Fraction By Weight: 2-5%

OSHA PEL 300 PPM (MFR)

ACGIH TLV: 300 PPM (MFR)


TOLUENE (SARA 313) (CERCLA)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 1-3%

OSHA PEL 200 PPM

ACGIH TLV: 50 PPM, S

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ASPIR HAZ. DO NOT

RTECS: 9999999ZZ


DROWSY/UNCON, PLACE ON LEFT SIDE W/HEAD DOWN. IF

RTECS: 9999999ZZ


EXPOS TO HIGH

RTECS: 9999999ZZ


EPINEPHRINE AND OTHER SYMPATHOMIMETIC DRUGS MAY

RTECS: 9999999ZZ


IT WILL BE NEC TO ESTABLISH & MAINTAIN ADEQ

RTECS: 9999999ZZ


TO OTHER PARTS OF BUILDING; & PERSONS WHO ARE

RTECS: 9999999ZZ


AVOID THE WORK AREA DURING THIS PROCESS.

RTECS: 9999999ZZ


ASSURE FRESH AIR ENTRY AND EXHAUST DURING USE AND

RTECS: 9999999ZZ


WASH THOROUGHLY AFTER CONTACT, W/WATERLESS &

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES: CAN CAUSE SEV IRRIT,
BLURRED VISION. SKIN: CAN CAUSE SEV IRRIT. PRLNG/RPTD CONT CAN
CAUSE DERM. INHAL: BRTHG VAPS CAN CAUSE RESP TRACT IRRIT, HDCH,
DROW & OTHER CNS EFTS. IN EXTREME CASES , ASPHY MAY OCCUR. INGEST:
CAN CAUSE GASTRIC DISTURB, HDCH, DROW & OTHER CNS EFTS. VERY LGE
QTYS MAY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:HEAVY NAPHTHENIC DISTILLATE SOLVENT
EXTRACTS: IARC MONO, SUPP, VOL 7, PG 252, 1987: GROUP 1.
Effects of Overexposure:HLTH HAZ: RSLT IN INTESTINAL OBSTRUCTION.
SWALLOWING/VOMIT CAN CAUSE ASPIR PNEUMIT EVIDENCED BY COUGHING,
LABORED BRTHG & BLUISH SKIN; IN SEV CASES, THIS CAN BE FATAL.
CHRONIC: OCCUP OVEREXP TO SOLVS MAY LEAD TO PERM BRAIN & NERV SYS
DMG. EXPOS TO HIGH CONCS OF TOLUENE HAS CAUSED PERM DMG TO HUMAN
DNA & HARM (SUP DAT)
Medical Cond Aggravated by Exposure:PREEXISTING SKIN, LUNG AND HEART
DISORDERS.

First Aid

First Aid:EYE: IMMED FLUSH W/PLENTY OF RUNNING WATER FOR AT LEAST 15
MIN, LIFTING UPPER & LOWER LIDS OCCAS. REMOVE CONT LENSES. GET
IMMED MED ATTN. SKIN: REMOVE CONTAM SHOES & CLTHG & THORO WASH
AFFECTED AREA W /SOAP & WATER. IF IRRIT/REDNESS DEVELOPS, GET IMMED
MED ATTN. INHAL: REMOVE TO FRESH AIR. IF BRTHG IS DFCLT, ADMIN
OXYGEN. IF BRTHG HAS STOPPED, GIVE ARTF RESP. KEEP PERS WARM, QUIET
& GET (ING 5)

Fire Fighting

Flash Point Method:SCC
Flash Point:>200F,>93C
Extinguishing Media:WATER SPRAY, DRY CHEMICAL, FOAM, OR CARBON DIOXIDE.
WATER OR FOAM MAY CAUSE FROTHING.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . WATER MAY BE USEFUL IN COOLING CONTAINERS EXPOSED TO
HEAT.
Unusual Fire/Explosion Hazard:MATERIAL CAN SPLATTER ABOVE 212F. DRY
FILM CAN BURN. CLOSED CONTAINERS EXPOSED TO EXTREME HEAT MAY
RUPTURE DUE TO PRESSURE BUILD-UP.

Accidental Release

Spill Release Procedures:WEAR APPROPRIATE PROTECTIVE EQUIPMENT IF
NECESSARY. SCOOP MATERIAL INTO CONTAINER AND REMOVE TO SAFE PLACE
TO DRY. USE CAUTION: FLOOR MAY BE SLIPPERY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID EXTREME HEAT/COLD. KEEP OUT OF
REACH OF CHILDREN. USE ONLY AS DIRECTED ON LABEL. CLOSE CONTR AFTER
EACH USE. DO NOT REUSE CONTR.
Other Precautions:AVOID SKIN & EYE CONT. WORK SITE ENVIRON: INITIALLY
THERE MAY BE A POTENTIAL ADVERSE IMPACT ON INDOOR AIR QUALITY W/IN
GEN WORK AREA DURING INSTALLATION PROCESS. THEREFORE YOU SHOULD
ADVISE THE BLDG M ANAGER/OTHER APPROP PERS THAT (ING 9)

Exposure Controls

Respiratory Protection:WEAR CORRECT NIOSH APPROVED RESPIRATORY
PROTECTION WHEN VENTILATION IS NOT ADEQUATE.
Ventilation:VENT MUST BE ADEQ TO KEEP EXPOS BELOW ESTABLISHED LIMS.
OPEN ALL WINDOWS & DOORS & UTILIZE OTHER MEANS TO (ING 12)
Protective Gloves:NITRILE RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA . WEAR IMPERVIOUS CLOTHING AS NEEDED.
Work Hygienic Practices:AVOID BRTHG VAP. AVOID PRLNG/RPTD CONT W/SKIN.
REMOVE CONTAM CLTHG & SHOES & THORO CLEAN BEFORE REUSE. (ING 13)
Supplemental Safety and Health
EFTS OF OVEREXP: TO ANIMAL FETUSES. EXPOS TO VAPS SHOULD BE MINIMIZED.
CAN CAUSE SKIN CANCER. PERS RISKS CAN BE MINIMIZED BY OBSERVING
GOOD WORK PRACT & PERS HYGIENE. TOLUENE APPEARS ON NAVY OCCUP CHE M
REPRO HAZ LIST. CONSULT APPROP HLTH PROFESSIONALS CONCERNING LATEST
HAZ LIST INFO & SAFE HNDLG & EXPOS INFO .

Chemical Properties

Boiling Pt:B.P. Text:>212F,>100C
Vapor Density:HVR/AIR
Spec Gravity:1.44
VOC Pounds/Gallon:61
VOC Grams/Liter:.51
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:DISPERSIBLE
Appearance and Odor:TAN PASTE; SOLVENT ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, BASES AND OXIDIZING AGENTS.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION MAY PRODUCE
FUMES AND SMOKE AS IN OIL AND RUBBER FIRES.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS. DO NOT FLUSH ADHESIVE DOWN DRAINS.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.